Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	37
Date	08/07/14
Start Time	16:17:55
Diameter Midpoint
 11.3	504734
 11.8	541128
 12.2	543615
 12.6	565693
 13.1	596248
 13.6	632913
 14.1	656294
 14.6	682751
 15.1	716673
 15.7	742350
 16.3	757993
 16.8	788886
 17.5	812401
 18.1	828712
 18.8	849142
 19.5	863091
 20.2	870373
 20.9	864428
 21.7	845780
 22.5	826773
 23.3	794453
 24.1	745471
 25.0	697253
 25.9	646331
 26.9	589658
 27.9	522241
 28.9	471902
 30.0	416527
 31.1	374013
 32.2	333044
 33.4	293588
 34.6	261598
 35.9	232654
 37.2	200055
 38.5	173510
 40.0	152328
 41.4	134237
 42.9	120678
 44.5	111086
 46.1	102922
 47.8	96238.3
 49.6	89711.6
 51.4	83551.4
 53.3	76330.7
 55.2	69442.2
 57.3	62967.3
 59.4	57838.4
 61.5	50550
 63.8	43425.7
 66.1	37494.8
 68.5	32361.6
 71.0	27287
 73.7	22848
 76.4	18718.9
 79.1	15019.3
 82.0	11841.4
 85.1	8868.37
 88.2	6966.21
 91.4	5352.84
 94.7	4544.06
 98.2	3846.7
101.8	3312.38
105.5	2638.24
109.4	2220.1
113.4	1825.04
117.6	1511.95
121.9	1281.27
126.3	1038.38
131.0	824.772
135.8	719.156
140.7	548.048
145.9	446.212
151.2	377.66
156.8	294.176
162.5	242.473
168.5	156.615
174.7	145.196
181.1	99.0684
187.7	88.3115
194.6	96.1381
201.7	71.3985
209.1	44.8879
216.7	54.3776
224.7	32.3655
232.9	44.0517
241.4	31.6565
250.3	23.1764
259.5	26.8951
269.0	19.1988
278.8	22.9986
289.0	32.2865
299.6	18.3197
310.6	30.148
322.0	13.9893
333.8	16.1737
346.0	25.2997
358.7	15.1049
371.8	21.038
385.4	12.6327
399.5	1.74257
414.2	6.91535
429.4	7.04795
445.1	4.75858
461.4	14.5634
478.3	2.47241
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6949
High Voltage	9940.71
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	20.0387
Mean(nm)	22.5691
Geo. Mean(nm)	20.7831
Mode(nm)	20.1691
Geo. Std. Dev.	1.46987
Total Concentration(#/cm)	2.27072e+007
Comment	